2023—2025年安阳市部分托幼机构 消毒质量监测结果分析
摘要
图/表
参考文献
相似文献
本文已被:浏览 7965次   下载 0次
    
中文摘要: 摘 要 :目的:掌握安阳市各级、各类托幼机构消毒质量现况,发现托幼机构预防性消毒过程中的薄弱环节,有针对性 地的采取相应措施,规范托幼机构消毒流程。方法:2023—2025年采用现场采样的方法连续3年对安阳市部分托幼机构进 行消毒质量监测。监测对象包括物体表面、工作人员手、紫外线辐射强度等,样品采集、检测及评价依据《医院消毒卫生标 准 》( GB 15982—2012)、《医疗机构消毒技术规范》( WS/T 367—2012) 等进行,采用x² 检验对监测结果进行分析。结果: 共检测样品4367份,总体合格率为77.90%(3402/4367),2023 — 2025年各年份消毒质量监测合格率比较,差异有统计学 意 义( x²=51.495,P<0.05) 。 物体表面、工作人员手、紫外线灯辐射强度监测合格率分别为84.86%、52.36%、72.84%, 三者比较,差异有统计学意义 ( x²=39.077,P<0.05) 。 公办托幼机构、民办托幼机构消毒质量监测合格率分别为80.16%、 73.10%,两者比较,差异有统计学意义( x²=27.498,P<0.05); 市区托幼机构、县区托幼机构消毒质量监测合格率分别 为74.50%、78.78%,两者比较,差异有统计学意义( x²=7.575,P<0.05) 。 结论:安阳市托幼机构总体消毒质量监测合格 率较低,工作人员手卫生质量情况为核心薄弱环节,需加强相关监督和管理。
中文关键词: 关键词:托幼机构  消毒  合格率
Abstract:Abstract: OBJECTIVE To assess the disinfection quality in childcare facilities of various types and levels in Anyang,identify weak links in the preventive disinfection process,and provide evidence for implementing targeted measures to standardize disinfection procedures in these settings.METHODS From 2023 to 2025,on-site sampling was conducted continuously to monitor disinfection quality in selected childcare facilities in Anyang.The monitored parameters included object surfaces,staff hands,and ultraviolet(UV)lamp radiation intensity.Sample collection,testing,and evaluation were performed in accordance with the Hygienic Standard for Hospital Disinfection(GB 15982-2012)and the Technical Specification for Disinfection in Healthcare Facilities(WS/T 367-2012).The x² test was used to analyze the surveillance results.RESULTS A total of 4,367 samples were tested,with an overallqualified rate of 77.90% (3,402/4,367).The difference in annual qualified rates from 2023 to 2025 was statisticall significant(x²=51.495,P<0.05).The qualified rates for object surfaces,staff hands,and UV lamp radiation intensity were 84.86%,52.36%,and 72.84%,respectively, with a statistically significant difference among the three(x²=359.529,P<0.05).Public childcare facilities had a significantly higher qualified rate(80.16%)compared to private ones(73.10%)(x²=39.077,P<0.05).Facilities located in urban areas had a qualified rate of74.50%,which was significantly lower than that of facilities in county-level areas(78.78%)(x²=7.575,P<0.05). CONCLUSION The overalldisinfection quality in childcare facilities in Anyang is suboptimal,with staff hand hygiene being the critical weak link.Enhanced supervision and management are urgently needed.
文章编号:3202410012     中图分类号:R175    文献标志码:
基金项目:
Author NameAffiliation
  
引用文本:


用微信扫一扫

用微信扫一扫